Wilner-Greene Associates, Inc. 10 Forest Falls Unit#1A
Yarmouth Maine, 04096

Tel: (800) 634 - 4327
Fax: (207) 847 - 9227
Email: dave@wilner-greene.com
Home
Calibrations
Rentals
About Us
Air Sampling Pumps
Air Velocity Meters
Clinical, Diagnostic
Audiometers & Tympanometers
Gas Detector Tubes
Hazmat Detection Kit
Hearing Aid Dispensing
Equipment
Heat Stress Monitors
Indoor Air Quality Monitors
Noise Dosimeters
OAE Test Systems
Occupational Health Medical
Screening Equipment
Primary Air Flow Calibrators
Screening Audiometers
Screening Tympanometer
Sound Level Meters
Titmus Vision Screeners
Vibration Monitors
Hot Sales
Sitemap
Partner Links
Hot Sales
Vibration Monitors, Indoor Air Quality Monitors, Air Velocity
» more
Wilner-Greene Associates, Inc.

Primary Air Flow Calibrators

Primary airflow calibrators are used for calibrating personal sampling pumps, which are key tools for exposure assessment. The accuracy of sampling depends on how much air passes through the sampling media, which is where air flow calibrators are needed, and good laboratory analysis. Sampling pumps should be calibrated before and rechecked after sampling using a primary airflow calibrator.


TSI Model 4146 Primary Air Flow Calibrator

The Model 4146 primary airflow calibrator has a range of 0.01 to 20L/min (liters per minute). The 4146 is a small, portable, battery-operated calibrator that is lightweight and easy to use. Volumetric flow rate is continuously displayed so that adjustments to pump flow can be made in real-time. This primary airflow calibrator is accurate to 2% of reading.

Features and Benefits of the TSI 4146 Primary Air Flow Calibrator:
  • Continuous real-time volumetric flow rate readings. Pump adjustment and calibration is fast and easy
  • Battery powered, compact and lightweight
TSI Air Velocity Meter
  • Use the same primary air flow calibrator for adjustment, calibration and periodic checks
  • Comes with a NIST traceable calibration certificate
  • Kits come complete and ready to use

Applications:
  • Industrial hygiene sampling
  • Environmental Sampling
  • Indoor air quality
  • Epidemiology health studies
  • Field services


Mini-BUCK Model M-5 Primary Air Flow Calibrator

This primary airflow calibrator is ideal for day-to-day flow verification and calibration of your personal and environmental sampling pumps. It is small, compact, lightweight, rugged, fast and accurate at any altitude. This primary airflow calibrator gives you the advantage of accuracy and portability in one compact package.

Features and Benefits of the Mini-BUCK M-5 Primary Air Flow Calibrator:
  • Compact, lightweight & easy to use
  • Dimensions: 5.5L x 6W x 2.5D inches, 14L x 15.3W x 6.4D cm
  • Weight: 2 lbs
  • Microprocessor controlled for fast, accurate, repeatable measurements
Mini-BUCK Model M-5 Primary Air Flow Calibrator
  • Instant readout of volumetric flow rate for either vacuum or pressure
  • Flow range: 1-6000 cc/min
  • Accuracy +/- 0.5% of any display reading
  • Works at any altitude without correction
  • Temperature limits: 32º to 104º F (0º to 40º C)
  • 4.8V Ni-Cad battery pack with 8-hour continuous use rating
  • Certificate of calibration shipped with each unit
  • One year warranty on parts and labor


Sensidyne's GILIBRATOR-2 Air Flow Calibrator

Sensidyne's GILIBRATOR-2 air flow calibrators provides the user with a convenient and automated way to check almost any air sampling pump for proper air flow and function before their deployment. This primary airflow calibrator system is made up of a GILIBRATOR-2 Base, which is used with the three sizes of wet bubble cells. These interchangeable components are also available as part of kits which can also include a complete calibration diagnostic panel. All cells twist on the base for easy mounting.

Features & Benefits of GILIBRATOR-2 Base:
  • Easy to operate
  • Microprocessor-controlled unit w/LCD touch pad screen
  • Displays flow rate, multiple flow samples, & the sample number
  • Light weight, operates on AC power or 8 hour battery life
Sensidyne's GILIBRATOR-2 Air Flow Calibrator
Features & Benefits of GILIBRATOR-2 Diagnostic Kits:
  • "Load" simulation - Offers two load simulations for high and low flows to imitate line back-pressures
  • Back pressure reading - A built in Magnehelic gauge allows visual monitoring of in-line back pressures up to 30" H2O
  • Leak Checking - Built-in Magnehilic gauge allows visual leak testing and monitoring capabilities
  • Pump flow adjustment - Rotameters allow instant visual indication of approximate flow rates, assisting in properly adjusting airflows.

Please call with any questions regarding our Primary Air Flow Calibrators.


Air Velocity Meters

Air Velocity Meters give you the capability for making a wide variety of velocity, temperature, and air volume measurements. You can also log data for later detailed analysis and report generation. All Air Velocity Meters offered through Wilner-Greene are easy to use from the first time you pick them up. All models measure velocity and temperature, calculate flow rate, perform multi-value averaging, and determine minimum and maximum readings. All of the Air Velocity Meters feature durable telescoping probes with etched length marks. Advanced models of these air velocity meters add a humidity measurement and perform dew point and wet bulb temperature calculations. Two models also include articulated probes.

VelociCalc® Air Velocity Meters

TSI's VelociCalc® Air Velocity Meters are easy to use from the first time you pick them up. The Models 8345 and 8346 measure velocity and temperature, calculate flowrate, perform multi-value averaging and determine minimum and maximum readings. The models 8347 and 8347(A) add a humidity measurement and perform dew point and wet bulb temperature calculations.

Features & Benefits of VelociCalc Air Velocity Meter:
  • Extended velocity range of 0 to 6,000 ft/min
  • Temperature range of 0 to 140° F or more
  • Humidity range of 0 to 95% rh (Models 8347 and 8347(A) only)
  • Easy to read digital display
  • Variable time constant modes available for a steady display when measuring fluctuating flows
  • Telescoping probes with etched length marks to make duct traverse measurements easier
  • Sampling function allows for easy recording of multiple measuring points
  • Direct calculation of dew point and wet bulb temperatures
VelociCalc® Air Velocity Meter
Please call with any questions regarding our Air Velocity Meters.