Clinical, Diagnostic Audiometers & Tympanometers
Interacoustics AZ26 Clinical Middle Ear Analyzer
|
| The AZ26 clinical impedance audiometer is built to meet the demands of clinics and hearing specialists who require a comprehensively specified middle ear analyzer. Tympanometry with a range of pressure limits is available together with an extensive test battery of acoustic reflex tests, which include reflex decay and latency measurement. Eustachian Tube Function may be evaluated even with a perforated eardrum. To permit the easy checking of hearing thresholds, an air conduction audiometer is incorporated with the AZ26. |
 |
|
Features & Benefits of the Interacoustic AZ26 Audiometer:
- All testing can be performed manually or automatically
- Pre programmable test sequences may be run automatically
- Quick and easy diagnostic evaluation
- High resolution LCD screen
- All tests are presented on-line as clear graphical records
- Available printer
FONIX 7000 Hearing Aid Test System
|
| The FONIX 7000 test system combines unbeatable accuracy, speed, and innovative measurements with a flexible, easy-to-use interface that will fit the needs of any hearing health professional. The 7000-test system has a flexible user interface and a colorful, high-resolution display. Users navigate from screen to screen using the function and exit buttons. Each test screen has a help menu describing all the different things that you can do, and a settings menu that lets you make all kinds of test adjustments. |
 |
|
Beginning users will appreciate the 7000-test system's smart default test settings, while advanced users will love the ability to fine-tune the system to meet the particular needs of the hearing aid being tested. Measurements can be performed quickly from within an automated test sequence, or you can perform individual measurements at you own pace.
Maico MI 34 Screening/Diagnostic Tympanometer
|
This screening/diagnostic tympanometer performs automatic impedance measurements for middle-ear evaluations. In seconds the results are displayed on the backlit LCD and can be printed from the internal printer after each test. Included in this model are special diagnostics testing for ipsi and contra reflexes, reflex decay and an intact Eustachian tube as well as perforated Eustachian tube function.
Features & Benefits of the Maico MI 34 Tympanometer:
- Ipsi and contra reflex testing
- Reflex decay testing
- Intact Eustachian tube function testing
- Perforated Eustachian tube function testing
- Adjustable comfort probe
- LCD graphical display
- Quiet, fast internal printer
|
 |
|
Interacoustics AT235h Middle Ear Analyzer |
| Interacoustics utilize two beneficial techniques to acquire tympanograms. The first is an endless airflow technique which improves the instrument's ability to obtain a tympanogram on difficult to test patients or when a slight leak is present. This prevents the system from continually resetting to continue the test. The second feature is an intelligently controlled pump system with an adaptive speed control. This feature combines a very fast test speed with high resolution of the tympanogram peak, which might otherwise be obtained, only with a slower pump speed. |
 |
|
Interacoustics AC33 Clinical Audiometer |
The AC33 is a two channel clinical audiometer which provides a wide range of input and output parameters, thus ensuring optimum test stimulus and transducer combinations.
The AC33 provides a high degree of flexibility in routing stimuli to outputs, allowing the clinician to perform a diverse range of tests. These may include ABLB, Stenger using tone or speech, binatural speech, tone in noise, and SISI with automatic scoring.
|
 |
|
Interacoustics AC40 Clinical Audiometer |
The AC40 is a state of the art, 2 channel clinical audiometer which can provide an advanced clinic with all of the necessary capabilities to perform traditional threshold and supra threshold examinations. The AC40 offers exceptional flexibility with selections of pre-programmed tests, user programmable tests and several automated tests.
Educational institutions will love the wide range of pre-programmed tests for teaching a variety of human auditory phenomenon. Classic tests like the ABLB, MLB, MLD, SISI, DLI, and DFI are presented with their own dedicated screen display. This facilitates the ease of use and clear understanding of the rationale behind the test.
|
 |
|
Features & Benefits of the AC40 Clinical Audiometer:
- Loudness scanning for evaluating subjective loudness growth
- Auto threshold test follows the Hughson Westlake procedure
- TheBe'ke'sy test features continuous or pulsed tone presentations
- Threshold Tone Decay works automatically in a time window of up to 420 seconds
- SISI test includes a familiarization feature and automatic score calculation
- Masking Limen Difference (MLD) test
- ABAB has its own dedicated screen
- Monaural Loudness Balancing (MLB)
|
|
Wilner-Greene Associates Inc, Sales, Calibrations, Rentalls, Clinical, Diagnostic Audiometers & Tympanometers, Interacoustics AZ26 Clinical Middle Ear Analyzer, FONIX 7000 Hearing Aid Test System, Maico MI 34 Screening/Diagnostic Tympanometer, Interacoustics AT235h Middle Ear Analyzer, Interacoustics AC33 Clinical Audiometer, Interacoustics AC40 Clinical Audiometer.
|
|
|